Home > Cms Error > Cms Error Invalid Pdu Mode Parameter

Cms Error Invalid Pdu Mode Parameter


To resolve this error, you need to manually define the operator SMSC address in the NowSMS configuration. CMS ERROR 21 "Short message transfer rejected" This cause indicates that the equipment sending this cause does not wish to accept this short message, although it could have accepted the short CMS ERROR 47 "Resources unavailable, unspecified" This cause is used to report a resource unavailable event only when no other cause applies. Send SMS with GSM Modem - CMS Error codes If you are trying to send an SMS messages with a GSM modem, the modem can return an error code in case http://trinitylabsupply.com/cms-error/cms-error-invalid-text-mode-parameter.html

more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed CMS ERROR 28 "Unidentified subscriber" This cause indicates that the subscriber is not registered in the PLMN (i.e. At what version? Example Applications of SMS Messaging 4.

+cms Error: 305

If you cannot, then there may be a problem with your account with the mobile operator. (Note: We have observed that with some mobile operators, if you buy a modem with CMS ERROR 10 "Call barred" This cause indicates that the outgoing call barred service applies to the short message service for the called destination. I have tried to send simple message that will say "hellohello". Commands look like this: AT+CMGF=0 // PDU mode Modem > OK AT+CMGS=20 // Send with message length >PDUtext Modem > +CMS ERROR: 304 qt sms send at-command pdu share|improve this question

E-mail: [email protected] If you have a technical question, please submit a support request on-line. Result Codes of AT Commands 17. When it sends 125 characters > (here, > all asterisks) it works fine: > > 2009-02-09 21:27:26 [2180] [6] DEBUG: AT2[/dev/com3]: --> AT+CMGS=125^M > 2009-02-09 21:27:26 [2180] [6] DEBUG: AT2[/dev/com3]: <-- Cms Error 2172 Sending SMS Messages from a Computer / PC Using AT Commands (AT+CMGS, AT+CMSS) 26.

Connect to the modem using HyperTerminal, and issue the command AT+CSQ. more hot questions question feed lang-cpp about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture / Recreation General Troubleshooting Tips Before I get into the full CMS ERROR code list, it may be worth offering some general troubleshooting tips, as the error codes themselves are usually quite cryptic. Image blending dependent on image column Are electric bike speed limitations set in stone?

Introduction to AT Commands 15. +cms Error: 330 Preferences - Do not show ads Page 23 of 65 Previous Page | Next Page Table of Contents Contents at a Glance 1. SMS & MMS Protocols NowSMS Features Developer APIs Mobile Operator MMSC How MMS Works What is a GSM Modem? problems in MAP. 21 - "Short message transfer rejected"This cause indicates that the equipment sending this cause does not wish to accept this short message, although it could have accepted the

Cms Error 500

The SIM card requires a password (e.g. http://smstools3.kekekasvi.com/topic.php?id=961 Can guns be rendered unusable by changing the atmosphere? +cms Error: 305 BR, Nikos ----- Original Message ----- From: "Bogus Bill" To: Sent: Tuesday, February 10, 2009 5:05 AM Subject: Invalid PDU mode parameter error > > Cms Error 304 asked 1 year ago viewed 4701 times active 1 year ago Upcoming Events 2016 Community Moderator Election ends in 3 days Related 4Why I am not able to receive sms using

Always restart the gateway service after making a change to the SMSGW.INI file. check my blog See +CMS error code 300 for the meaning of mobile equipment. 302 The operation to be done by the AT command is not allowed. 303 The operation to be done by What is an SMS Gateway? 10. Sat Nov 19, 2016 17:43 LoginRegisterSearchActiveTopicsTermsofUseContactAdmin • SMSTools3 Community » Help and support Bottom Invalid PDU mode parameter when trying send sms Login and Post Reply Page: 1 Author Post Szpadel Cms Error 111

What AT > command strings should I be tweaking to fix this? no channel, facility busy/congested etc.). CMS ERROR 8 "Operator determined barring" This cause indicates that the MS has tried to send a mobile originating short message when the MS's network operator or service provider has forbidden http://trinitylabsupply.com/cms-error/cms-error-invalid-parameter.html Login Register Change Language Danish German German (Informal) English French Croatian Italian Portuguese (Brazil) Swedish Turkish Chinese (Simplified) Chinese (Traditional) Chinese (Simplified) Chinese (Traditional) Croatian Danish English French German German (Informal)

There is no resolution for this problem, other than to use a different modem that does not suffer from this bug. +CMS ERROR 512 is defined as a manufacturer specific error. Cms Error Codes Hot Network Questions Has a Poké Ball ever captured anything other than a Pokémon? Why don't my users have separate desktops in Windows 10?

Table of +CMS Error Codes and Their Meanings The following table lists some of the +CMS error codes and their meanings. +CMS error code Meaning 300 Mobile equipment (ME) failure.

Help Legal Notice Terms of use Change style Round Solutions WoltLab Basic WoltLab Blue Sunrise Change style ----------------------- Round Solutions WoltLab Basic WoltLab Blue Sunrise Saturday, November 19th 2016, 6:43pm Go Should I be concerned about "security"? This cause is sent if the service request cannot be actioned because of congestion (e.g. Cms Error 300 This is my message format in Qt designer (which is irrelevant for this subject, I'm having problems with error 304 - invalid PDU mode parameter): QByteArray PDUtext; PDUtext[0] = 0x00; PDUtext[1]

However, the information element is not required to be present in the message in order for the equipment sending the cause to process the message. The AT command +CPIN (command name in text: Enter PIN) can be used to send the PIN to the SIM card. 312 The SIM card requires a PH-SIM PIN to operate. Under the section header for the modem configuration (e.g., [Modem - …], add SMSC=+phonenumber, where "+phonenumber" is the address of the SMSC. have a peek at these guys Below shows some common causes of +CMS errors: A SIM card is not present in the GSM/GPRS modem or mobile phone.

To determine if this is the problem, try going into "Properties" for the modem in the "SMSC" list of NowSMS, and change "SMS Access" to "GSM". +CMS ERROR 330 occurs frequently It's a good idea to check the signal strength of the modem, and possibly relocate the modem so that it can acquire a stronger signal from the mobile operator. +CMS ERROR Texas, USA speed ticket as a European citizen, already left the country What will you bring for Thanksgiving? Setting or Reading the Service Center Address / SMSC Address (AT+CSCA) 22.

What Makes SMS Messaging So Successful Worldwide? 3. Does it work?